{"product_id":"pre-owned-niton-xl5-plus-xrf-catalytic-converter-recycling-dibs","title":"Used Niton XL5 Plus Handheld XRF Analyzer for Catalytic Converter Testing","description":"\u003cp\u003eThe Niton XL5 Plus Handheld XRF Analyzer is a top-tier solution for catalytic converter testing, analysis, and recycling, delivering high-sensitivity measurement of platinum (Pt), palladium (Pd), and rhodium (Rh).\u003c\/p\u003e\n\u003cp\u003eThis pre-owned unit provides advanced performance for catalytic converter value testing, allowing recyclers and buyers to evaluate material, detect inconsistencies, and make confident purchasing decisions in real time.\u003c\/p\u003e\n\u003cp\u003eWith fast test times and strong precision across variable catalyst compositions, the XL5 Plus is built for demanding catalytic converter recycling workflows.\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e→ \u003c\/span\u003e\u003ca href=\"https:\/\/alloygeek.com\/pages\/contact\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ciframe width=\"560\" height=\"315\" src=\"https:\/\/www.youtube.com\/embed\/Mdsq5ocPn38?si=4nW5ihbW2og12v54\" title=\"YouTube video player\"\u003e\u003c\/iframe\u003e\u003c\/p\u003e\n\u003ch2\u003eAccurate PGM Analysis for Catalytic Converter Value\u003c\/h2\u003e\n\u003cp\u003eThe value of a catalytic converter is driven entirely by its platinum group metal (PGM) content, which can vary significantly between units—ranging from under $100 to over $1000 depending on composition .\u003c\/p\u003e\n\u003cp\u003eBecause of this variability, real-time, accurate measurement of:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003ePlatinum (Pt)\u003c\/li\u003e\n\u003cli\u003ePalladium (Pd)\u003c\/li\u003e\n\u003cli\u003eRhodium (Rh)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eis critical to:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003ePay the correct price for incoming material\u003c\/li\u003e\n\u003cli\u003eIdentify high-value converters or blends\u003c\/li\u003e\n\u003cli\u003eDetect adulterated or mixed material\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eHandheld XRF allows you to perform this analysis instantly, without waiting for lab results.\u003c\/p\u003e\n\u003ch2\u003eHigh-Sensitivity Platinum, Palladium, and Rhodium Detection\u003c\/h2\u003e\n\u003cp\u003eThe XL5 Plus is designed for high-performance catalytic converter analysis, offering excellent sensitivity and precision across a wide range of catalyst compositions.\u003c\/p\u003e\n\u003cp\u003eTypical Limits of Detection (3σ)\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003ePlatinum (Pt): ~9 ppm\u003c\/li\u003e\n\u003cli\u003ePalladium (Pd): ~3 ppm\u003c\/li\u003e\n\u003cli\u003eRhodium (Rh): ~3 ppm\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThese detection limits support accurate catalytic converter value testing, especially when working with lower-grade material or blended catalyst samples.\u003c\/p\u003e\n\u003ch2\u003eProven Accuracy Against Laboratory Methods\u003c\/h2\u003e\n\u003cp\u003eTesting across 120 catalytic converter samples shows excellent correlation between handheld XRF results and laboratory methods (fire assay + ICP), with:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e~5.0% average difference for Pt\u003c\/li\u003e\n\u003cli\u003e~3.9% for Pd\u003c\/li\u003e\n\u003cli\u003e~2.9% for Rh\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThis level of agreement demonstrates that handheld XRF is a reliable tool for real-time catalytic converter analysis, even across highly variable materials.\u003c\/p\u003e\n\u003ch2\u003eFrom Incoming Material to Catalyst Powder Analysis\u003c\/h2\u003e\n\u003cp\u003eCatalytic converter recycling typically involves:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eDecanning the converter\u003c\/li\u003e\n\u003cli\u003eCrushing and milling the ceramic substrate\u003c\/li\u003e\n\u003cli\u003eBlending and homogenizing material\u003c\/li\u003e\n\u003cli\u003eTesting using XRF in a sample cup\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003ePrepared material is typically reduced to \u0026lt;250 µm particle size before analysis to improve consistency .\u003c\/p\u003e\n\u003cp\u003eThe XL5 Plus supports:\u003c\/p\u003e\n\u003ch3\u003eIntact Converter Testing\u003c\/h3\u003e\n\u003cp\u003eFast screening for purchasing decisions and incoming inspection\u003c\/p\u003e\n\u003ch3\u003eCatalyst Powder Analysis\u003c\/h3\u003e\n\u003cp\u003eMore consistent and repeatable results using prepared samples and test stand setups\u003c\/p\u003e\n\u003ch2\u003eFast, High-Throughput Catalytic Converter Testing\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eTypical test time: ~30 seconds\u003c\/li\u003e\n\u003cli\u003eRapid results for real-time buying decisions\u003c\/li\u003e\n\u003cli\u003eHigh throughput for large-volume operations\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eHigher power and detector performance allow for:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eShorter test times at equal precision\u003c\/li\u003e\n\u003cli\u003eImproved sensitivity to PGMs\u003c\/li\u003e\n\u003cli\u003eMore consistent results across variable materials\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSave on a Proven High-Performance XRF Analyzer\u003c\/h2\u003e\n\u003cp\u003eA pre-owned XL5 Plus provides:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eHigh-end performance for catalytic converter testing\u003c\/li\u003e\n\u003cli\u003eLower upfront investment\u003c\/li\u003e\n\u003cli\u003eImmediate availability vs long lead times\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThis makes it an ideal option for operations needing high-sensitivity catalytic converter analysis without the cost of a new system.\u003c\/p\u003e\n\u003ch2\u003eOptimized for Catalytic Converter and Scrap Analysis\u003c\/h2\u003e\n\u003cp\u003eThe XL5 Plus includes Automotive Catalyst Mode, which uses a fundamental parameters (FP) approach to account for complex and variable catalyst compositions .\u003c\/p\u003e\n\u003cp\u003eThis allows for more accurate measurement of Pt, Pd, and Rh across real-world materials.\u003c\/p\u003e\n\u003cp\u003eAdditional modes can be configured to support broader scrap and alloy analysis where needed.\u003c\/p\u003e\n\u003ch2\u003eIs the XL5 Plus Right for Your Operation?\u003c\/h2\u003e\n\u003cp\u003eThis analyzer is ideal for:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eCatalytic converter recyclers handling high volumes\u003c\/li\u003e\n\u003cli\u003ePrecious metals buyers requiring higher sensitivity\u003c\/li\u003e\n\u003cli\u003eOperations performing catalyst powder analysis\u003c\/li\u003e\n\u003cli\u003eTeams needing accurate, repeatable PGM measurement\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eGet High-Sensitivity Catalytic Converter Testing\u003c\/h2\u003e\n\u003cp\u003eLooking for a high-performance XRF analyzer for catalytic converter recycling?\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e→ \u003c\/span\u003e\u003ca href=\"https:\/\/alloygeek.com\/pages\/contact\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/p\u003e\n\u003ch2\u003eResources\u003c\/h2\u003e\n\u003cdiv class=\"rte\"\u003e\n\u003cul\u003e\n\u003cli data-start=\"2965\" data-end=\"3050\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0591\/2671\/0411\/files\/AutoCatalyticConverter-AppNote_Niton_2026.pdf?v=1775303348\"\u003e\u003cspan class=\"relative -mx-px my-[-0.2rem] rounded px-px py-[0.2rem]\"\u003eThermo Scientific Niton Catalytic Converter XRF App Note\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003cli data-start=\"2965\" data-end=\"3050\"\u003e\u003ca aria-describedby=\"a11y-new-window-message\" rel=\"noopener\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0591\/2671\/0411\/files\/XL5_Plus_Spec_Sheet.pdf?v=1743510413\" target=\"_blank\"\u003e\u003cspan class=\"relative -mx-px my-[-0.2rem] rounded px-px py-[0.2rem]\"\u003eThermo Scientific Niton XL5 Plus Brochure\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003cli data-start=\"2965\" data-end=\"3050\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0591\/2671\/0411\/files\/Niton_XL5Plus_LOD_-_Alloy_21d12743-c8f2-4571-8742-53cd17460ade.pdf?v=1750256586\"\u003e\u003cspan class=\"relative -mx-px my-[-0.2rem] rounded px-px py-[0.2rem]\"\u003eThermo Scientific Niton XL5 Limits of Detection - Alloy\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003cli data-start=\"2965\" data-end=\"3050\"\u003e\u003ca aria-describedby=\"a11y-new-window-message\" rel=\"noopener\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0591\/2671\/0411\/files\/110-00118_USER_GUIDE_NITON_XL5_V_1.7_6265eea6-e837-4aa9-aae6-42e6fd5ba6a8.pdf?v=1743510414\" target=\"_blank\"\u003e\u003cspan class=\"relative -mx-px my-[-0.2rem] rounded px-px py-[0.2rem]\"\u003eThermo Scientific Niton XL5 Plus Manual\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e","brand":"Thermo Scientific","offers":[{"title":"Default Title","offer_id":45629354803339,"sku":"NITONXL5PLUS-CPO-GMM-CARCAT-DIBS","price":29990.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0591\/2671\/0411\/files\/ThermoScientificNitonXL5PlusCatalyticConverterRecyclingLeftViewv26.2.25.jpg?v=1772038173","url":"https:\/\/alloygeek.com\/products\/pre-owned-niton-xl5-plus-xrf-catalytic-converter-recycling-dibs","provider":"Alloy Geek","version":"1.0","type":"link"}