{"product_id":"xrf-316-stainless-steel-calibration-clip-for-sciaps-x-550-pb-handheld-xrf-analyzer","title":"XRF 316 Stainless Steel Calibration Clip for SciAps X-550 Pb Handheld XRF Analyzer","description":"\u003cp\u003eEnsure your SciAps X-550 Pb Handheld XRF Analyzer delivers accurate and reliable elemental analysis with this 316 stainless steel calibration standard.\u003c\/p\u003e\n\u003cp\u003e316 stainless steel standards are commonly used for handheld XRF verification because they contain chromium, nickel, and molybdenum in well known concentrations.\u003c\/p\u003e\n\u003cp\u003eThis reference material is designed for routine instrument verification and QA\/QC checks, helping operators confirm analyzer performance before testing unknown samples.\u003c\/p\u003e\n\u003cp\u003e316 stainless steel is a widely used engineering alloy with a well-characterized elemental composition, making it an ideal reference for verifying XRF performance during alloy identification, scrap metal sorting, PMI inspection, and manufacturing quality control.\u003c\/p\u003e\n\u003cp\u003eThe standard is mounted as a solid metal coupon on a keychain, making it easy to carry and perform quick verification checks in the field or shop environment.\u003c\/p\u003e\n\u003ch2\u003eKey Features\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e316 stainless steel reference material representative of a common engineering alloy\u003c\/li\u003e\n\u003cli\u003eSupports routine XRF calibration verification and performance checks\u003c\/li\u003e\n\u003cli\u003eDesigned for use with the SciAps X-550 Pb handheld XRF analyzer\u003c\/li\u003e\n\u003cli\u003eDurable stainless steel coupon suitable for repeated measurements\u003c\/li\u003e\n\u003cli\u003eConvenient keychain format for portable QA\/QC checks\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eAttribute\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaterial\u003c\/td\u003e\n\u003ctd\u003e316 Stainless Steel (Cr-Ni-Mo alloy)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePrimary Elements\u003c\/td\u003e\n\u003ctd\u003eFe, Cr, Ni, Mo (typical stainless alloy composition)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFormat\u003c\/td\u003e\n\u003ctd\u003eSolid coupon on keychain for handheld XRF measurement\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompatibility\u003c\/td\u003e\n\u003ctd\u003eHandheld XRF analyzers including SciAps X-550 Pb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApplication\u003c\/td\u003e\n\u003ctd\u003eCalibration standard \/ reference material\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eWhy Use a Calibration Standard?\u003c\/h2\u003e\n\u003cp\u003eRoutine verification using a known reference material is an important part of handheld XRF quality control procedures.\u003c\/p\u003e\n\u003cp\u003eUsing a 316 stainless steel standard is required to validate the instrument upon startup. It also gives you a pass\/fail reference should the results from your handheld XRF come into question.\u003c\/p\u003e\n\u003cp\u003eCalibration standards are commonly used by operators performing scrap metal recycling, PMI inspection, manufacturing QA\/QC testing, and alloy verification.\u003c\/p\u003e\n\u003ch2\u003eTypical Users\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eScrap metal recycling facilities\u003c\/li\u003e\n\u003cli\u003ePMI inspection companies\u003c\/li\u003e\n\u003cli\u003eManufacturing quality control teams\u003c\/li\u003e\n\u003cli\u003eMachine shops and fabrication facilities\u003c\/li\u003e\n\u003cli\u003eMetals testing laboratories\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eAny organization performing frequent handheld XRF measurements benefits from keeping a portable verification standard available.\u003c\/p\u003e\n\u003ch2\u003eCompatible Instrument\u003c\/h2\u003e\n\u003cp\u003eThis calibration standard is designed for use with the \u003ca href=\"https:\/\/alloygeek.com\/collections\/sciaps-x-550-pb-lead-paint-analyzer-hud-approved\"\u003eSciAps X-550 Pb Handheld XRF Analyzer\u003c\/a\u003e.\u003c\/p\u003e\n\u003cp\u003eIf you are unsure whether this standard is compatible with your analyzer or this process, contact Alloy Geek before ordering.\u003c\/p\u003e\n\u003ch2\u003eUsage Instructions\u003c\/h2\u003e\n\u003col\u003e\n\u003cli\u003ePower on the SciAps X-550 Pb handheld XRF analyzer and allow the instrument to complete its normal warm up cycle.\u003c\/li\u003e\n\u003cli\u003ePlace the 316 stainless steel calibration standard over the analyzer measurement window.\u003c\/li\u003e\n\u003cli\u003eRun a cal check on the instrument.\u003c\/li\u003e\n\u003cli\u003eVerify that the screen shows \"Pass\" and that measured elemental values for iron, chromium, nickel, and molybdenum fall within expected ranges for 316 before analyzing unknown materials.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch2\u003eAccessories Often Purchased Together\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/alloygeek.com\/products\/sciaps-x-550-pb-kapton-measurement-window-for-handheld-xrf-analyzer\"\u003eSciAps X-550 Pb Measurement Windows\u003c\/a\u003e (Kapton or Prolene)\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/alloygeek.com\/products\/sciaps-x-550-pb-desktop-test-stand-for-handheld-xrf-analyzer\"\u003eSciAps X-550 Pb Desktop Test Stand for office work\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/alloygeek.com\/products\/portable-test-stand-for-sciaps-x-550-pb-handheld-xrf-analyzer\"\u003eSciAps X-550 Pb Portable Test Stand for field work\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/alloygeek.com\/products\/sciaps-x-550-pb-battery-charger-kit\"\u003eSciAps X-550 Pb Battery Charger\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/alloygeek.com\/products\/sciaps-x-550-pb-power-adapter-wall-plug-for-handheld-xrf-analyzer\"\u003eSciAps X-550 Pb AC Power Adapter\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/alloygeek.com\/products\/lead-paint-calibration-block-reference-material-1-mg-cm2\"\u003eLead Paint Calibration Block\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/alloygeek.com\/products\/sciaps-x-550-pb-handheld-xrf-analyzer-battery-rechargeable-li-ion\"\u003eSciAps X-550 Pb Rechargeable Li-Ion Batteries\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003eHard Transport Case with Custom Foam\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/alloygeek.com\/products\/sciaps-x-550-pb-usb-cable-for-handheld-xrf-analyzer\"\u003eUSB Cable\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/alloygeek.com\/products\/handheld-xrf-32mm-sample-cups\"\u003eXRF Sample Cups\u003c\/a\u003e for Powders and Fluids\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003ch3\u003eWhat is an XRF calibration standard?\u003c\/h3\u003e\n\u003cp\u003eAn XRF calibration standard is a material with a known elemental composition used to verify that an analyzer is measuring elements accurately. It is used to run a \"Cal Check\" on your SciAps X-550 Pb.\u003c\/p\u003e\n\u003cp\u003eNote: There is no chemical report or chemical certificate for this item. \u003c\/p\u003e\n\u003ch3\u003eWhy use a 316 stainless steel reference?\u003c\/h3\u003e\n\u003cp\u003e316 stainless steel contains well defined concentrations of chromium, nickel, molybdenum, and iron, making it a useful alloy reference for verifying handheld XRF analyzer performance.\u003c\/p\u003e\n\u003ch3\u003eWhen should I use this 316 calibration standard?\u003c\/h3\u003e\n\u003cp\u003eMost handheld XRF analyzers perform internal calibration automatically, but periodic verification using a reference standard helps ensure measurement accuracy over time.\u003c\/p\u003e\n\u003ch3\u003eCan this standard be used in the field?\u003c\/h3\u003e\n\u003cp\u003eYes. The stainless steel coupon is mounted on a keychain so operators can easily carry it for quick verification checks during field work. Clip it to the wrist strap of your handheld XRF so it never gets lost. \u003c\/p\u003e","brand":"Alloy Geek","offers":[{"title":"Default Title","offer_id":46202379796619,"sku":"SCIAPS-X550PB-316STD","price":250.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0591\/2671\/0411\/files\/SciApsX-550Pb316CalibrationClipv26.3.15.jpg?v=1773586637","url":"https:\/\/alloygeek.com\/products\/xrf-316-stainless-steel-calibration-clip-for-sciaps-x-550-pb-handheld-xrf-analyzer","provider":"Alloy Geek","version":"1.0","type":"link"}